Congratulations on our company's zirconia oxygen analyzer being applied to the Panzhihua Iron and Steel project
Release time: 2022-12-09
Congratulations on our company's zirconia oxygen analyzer being used in the Panzhihua Iron and Steel Group heating furnace project to measure the oxygen content of the furnace flue gas. Model: TFXL-8600, operating temperature: 0-1600℃.
Zirconia oxygen analyzer technical parameters. ZrO2-5 type, ZOY type, ZO-12B type, AZ20 type, ZR22G type zirconia oxygen analyzer technical parameters are as follows.
Zirconia analyzer display screen: LCD
Zirconia analyzer operating language: Chinese (English optional)
Zirconia oxygen analyzer power supply: 200-245V AC 50~60Hz
Zirconia oxygen analyzer power: ≤150W
Zirconia oxygen analyzer output signal: 4~20mA
Zirconia oxygen analyzer range: Factory default 0.01%-25%. Optional 0.01ppm-20000ppm, 0.01%-100%
Zirconia oxygen analyzer communication: HART/485 (optional)
Zirconia oxygen analyzer alarm: 1-way switch output (optional)
Zirconia analyzer instrument accuracy: ±0.75% or 0.05% O2 of the reading, whichever is larger; ******Detection limit is -0.05% O2
Zirconia analyzer repeatability: ±0.5% of full scale
TFEX-8 zirconia analyzer basic error: ≤±0.5% (full scale)
Zirconia oxygen analyzer stability: ≤±0.5% (instrument continuous calibration for 4h)
Zirconia oxygen analyzer response time: 90% response within 5 seconds. (Measured from when the gas enters the calibration gas inlet and the analog signal begins to change.)
Zirconia probe material: 304, 316L, 310S
Currently, our company produces zirconia oxygen analyzers with models such as: TFZO-5/TFXL-8/ZO-12B/CE-2C/ISG-CE/NFZRO2/NFEXZROW/YB-88/OXT3PC, etc. Mainly used for measuring flue gas oxygen content.
Zirconia probe protective tube diameter: φ45mm (default), φ32mm, φ38mm, φ51mm
Zirconia flange: JIS-5K-65-FF (standard), can be specified by the customer (DN50/DN65/DN80/DN100)
Zirconia probe heating furnace resistance: 55-65Ω (other resistance values can be customized.)
Zirconia protection level: IP65
Zirconia analyzer calibration method: Semi-automatic calibration, full-automatic calibration is optional.
Zirconia ambient temperature: -10℃~55℃
Zirconia sample gas temperature: ≤700℃
Zirconia flue gas flow rate: 0-50m/s
Zirconia analyzer sample gas pressure range: -30kpa~﹢5kpa (high-pressure scheme can be customized.)
Zirconia probe installation angle: Horizontal, vertical downward.
Calibration gas: 5% and 20.6% O2, background gas is nitrogen. Calibration gas flow rate: 150-300 ml/min
Self-diagnosis information: Thermocouple reverse connection, thermocouple disconnection, heating abnormality, temperature upper and lower limit alarm, oxygen content upper and lower limit alarm.
Anhui Tianfen Instrument Co., Ltd. Professional manufacturer of zirconia oxygen analyzers Focusing on the research and development and production of gas analyzers
Contact person for orders: Pan Xueliang
Contact number: 18225808093