Anhui Tianfen Instruments successfully registered the "ZIROX" trademark, leveraging brand strength to lead the new frontier in oxygen analysis technology.

Release time: 2025-11-07


Anhui Tianfen Instruments Successfully Registered “ZIROX” Trademark: Leading the New Frontier of Oxygen Analysis Technology with Brand Power

Recently, a leading domestic manufacturer of high-end zirconia oxygen analyzers —— Anhui Tianfen Instrument Co., Ltd. officially announced to the public its core brand, “ZIROX” The trademark has been approved for registration by the National Intellectual Property Administration. This significant milestone not only marks a crucial step forward for the company in brand building and intellectual property protection, but also underscores its unwavering commitment and strong capabilities in pioneering industrial process gas analysis with proprietary core technologies.

Deeply cultivate core technologies, forging professional excellence.

Since its establishment, Anhui Tianfen Instrument Co., Ltd. has remained dedicated to the research and development, production, and technological innovation of zirconia oxygen analyzers. The company deeply understands that, in challenging industrial environments characterized by high temperatures and corrosive conditions, accurate and stable oxygen measurement is crucial for enhancing combustion efficiency, ensuring production safety, and achieving energy conservation and emission reduction. To this end, Tianfen Instrument has assembled an experienced R&D team and consistently invested resources to overcome a series of technical hurdles—ranging from sensor material formulations and high-temperature sealing processes to advanced signal-processing algorithms—ultimately establishing a core technology system backed by fully independent intellectual property rights.

The company’s range of zirconia oxygen analyzers, oxygen probes, and transmitters has been widely adopted across multiple industries—including power generation, metallurgy, petrochemicals, building materials, and ceramics—thanks to their exceptional measurement accuracy, outstanding long-term stability, and robust environmental adaptability. These products have earned the trust and high praise of numerous customers.

“ZIROX” Set sail and usher in a new chapter of branded development.

The successfully registered this time “ZIROX” The trademark's name originates from the English term for zirconium oxide. “Zirconia Oxide” At its core lies a word root that embodies professionalism, focus, and innovation. It’s not just a simple logo—it’s a powerful representation of Anhui Tianfen Instrument’s cutting-edge technology, exceptional quality, and dependable service.

Successfully registered ‘ZIROX’ The trademark is a crucial component of our company's growth strategy. The head of Anhui Tianfen Instrument Co., Ltd. stated, In the past, we established a solid foothold in the market thanks to our strong technology and superior products; now, ‘ZIROX’ It will empower us with stronger brand value. It represents our commitment to customers: every machine bearing the ‘ZIROX’ Our flagship products embody our core technology and have all undergone rigorous quality control. Through this brand, we aim to convey China's expertise in the high-end analytical instruments sector to global markets.

Looking ahead: Driving innovation to empower a green industry

Looking ahead, Anhui Tianfen Instrument Co., Ltd. will focus on “ZIROX” The successful registration of the brand marks a new starting point—let's continue to persevere. Technology-driven enterprise, brand-strengthening enterprise The company’s development philosophy. We will further increase our R&D investment, dedicating ourselves to creating gas analysis solutions that are smarter, more precise, and better suited to the future needs of industry—particularly in supporting the nation. Dual Carbon The goal is to play a more significant role in promoting energy conservation and emission reduction in the industrial sector.

“ZIROX” The launch marks the beginning of Anhui Tianfen Instrument's remarkable transformation—from a solidly established technology-driven product supplier into an industry-influential brand enterprise. Empowered by its growing brand strength, Anhui Tianfen Instrument is poised to deliver even greater value to industrial customers worldwide and continue leading the way on the exciting new frontier of oxygen analysis technology.

About Anhui Tianfen Instrument Co., Ltd.:

Anhui Tianfen Instrument Co., Ltd. is a high-tech enterprise specializing in the research and development, production, sales, and service of industrial online analytical instruments. The company's flagship product, the zirconia oxygen analyzer, boasts cutting-edge technology and reliable performance, making it widely used in various industrial furnaces and process control systems. It provides customers with robust technical support, enabling precise oxygen control, energy savings, reduced consumption, and enhanced safety and environmental protection.

Contact number: 18225808093

Recommended product

Trace oxygen analyzer, oxygen analyzer, zirconia oxygen analyzer, ppm oxygen content analyzer


Zirconia-based trace oxygen analyzers (typically with a measurement range of 0.01 ppm to 5,000 ppm O₂) offer key advantages: high-temperature stability, ppm‑level accuracy, rapid response, and continuous operation. They are widely used for trace oxygen monitoring, inert‑atmosphere protection, and quality control of high-purity gases. **Metallurgy / Steel Industry (Heat Treatment / Protective Atmospheres):** Applications include nitriding furnaces, annealing furnaces, heating furnaces, converter flue gases, and glove boxes. Functions: In controlled-atmosphere furnaces (ppm‑level), precise oxygen control (10–1000 ppm) prevents oxidation and decarburization of workpieces, enhancing hardness and wear resistance. In vacuum/glove box environments, maintaining O₂ levels below 50 ppm protects lithium‑battery materials, rare metals, and precision components. **Semiconductors / Electronics (High‑Purity Gases / Cleanroom Environments):** Applications encompass diffusion/oxidation furnaces, wafer annealing, LED epitaxy, vacuum chambers, glove boxes, and high‑purity nitrogen, argon, and hydrogen pipelines. Functions: Ultra‑high‑purity gases (0.01–1 ppm) ensure process yield by preventing oxidation defects in silicon wafers, chips, and LED dies. Inert atmospheres (10–100 ppm) maintain an oxygen‑free environment, safeguarding sensitive materials and devices. **Air Separation / Industrial Gases (High‑Purity Gas Quality Control):** Applications include air‑separation units (N₂/O₂/Ar), high‑purity gas filling, pipeline transport, and cylinder inspection. Functions: Monitoring trace oxygen levels (0.1–10 ppm) in N₂/Ar streams ensures compliance with purity standards (e.g., high‑purity nitrogen ≥99.999%). **Food / Pharmaceutical Industries (Preservation / Aseptic Conditions):** Applications cover food packaging (nitrogen flushing or modified‑atmosphere packaging), pharmaceutical lyophilization and packaging, fermentation tanks, and aseptic isolators. Functions: Residual oxygen levels in packaging (0.1%–5%) inhibit oxidation and mold growth, extending shelf life for meat products, fruits, vegetables, and pharmaceuticals. **Laboratories / Research (Precision Environments):** Applications include materials R&D, battery laboratories, catalytic reaction studies, inert‑gas‑protected experiments, and glove boxes. Functions: Precise control of oxygen partial pressures (from ppm to % levels) enables simulation of oxygen‑free or low‑oxygen conditions, ensuring experimental reproducibility and data reliability. **Technical Specifications:** - Measurement range: 0.1 ppm–20,000 ppm; 0–20.6%; 0–100% - Output signal: 4–20 mA; load resistance ≤500 Ω - Communication interface: RS‑485 - Resolution: 0.01 ppm - Repeatability: ±0.5% of full scale - Basic error: ≤±1% (full scale) - Stability: ≤±1% (after 4 hours of continuous calibration) - Response time: Within 5 seconds when a standard gas is introduced to the sensor, reaching 90% of the final reading - Sample gas flow rate: Adjusted via flow meter, typically maintained at 0.1–0.2 NL/min - Ambient temperature: 0°C–45°C - Power supply and power consumption: 220 VAC ±10%, maximum power consumption 150 W - Sample gas temperature: 0–50°C - Sampling method: Either suction‑type or direct‑injection - Operating pressure (without pump): 0.05 MPa < inlet gauge pressure < 0.35 MPa, with stable atmosphere - Operating pressure (with pump): Micro‑positive, micro‑negative, or atmospheric pressure - Background gases: He, Ar, CO₂, N₂, and other inert gases mixed as needed - Gas‑line interface: 1/8-inch φ6 ferrule or quick‑connect fitting
Learn More