TFYHG™ Oxygen Content Analyzer for Rich Combustion

Oxygen analyzers, also known as oxygen concentration analyzers, are primarily used to measure the oxygen content in boiler flue gas. Flue gas oxygen content is one of the important monitoring parameters for boiler operation and an important indicator of the completeness of combustion equipment and boiler operation. Its value is related to factors such as boiler structure, type and properties of fuel, boiler load, operating air distribution conditions, and equipment sealing conditions. The smaller the oxygen content, i.e., the smaller the excess air coefficient, the greater the increase in chemical incomplete combustion heat loss and mechanical incomplete combustion heat loss; the larger the oxygen content, i.e., the larger the excess air coefficient, the greater the amount of air supplied. Excess air causes a decrease in furnace temperature, which not only affects combustion but also carries away a large amount of heat and dust, increasing the calculated results of pollution emission concentration. At the same time, a large air volume also increases the exhaust gas power consumption. Controlling the flue gas oxygen content is of great significance to controlling the combustion process and achieving safe, efficient, and low-pollution emissions. Technical parameters of the oxygen analyzer are as follows: Zirconia analyzer display screen: LCD Zirconia analyzer operating language: Chinese (English optional) Zirconia analyzer power supply: 200-245V AC 50~60Hz Zirconia transmitter power: ≤150W Zirconia transmitter output signal: 4~20mA Zirconia analyzer range: Factory default 0.01%-25%. Optional 0.01ppm-20000ppm, 0.01%-100% Zirconia analyzer communication: HART/485 (optional) Zirconia analyzer alarm: 1-way switch output (optional) Zirconia analyzer instrument accuracy: ±0.75% or 0.05% O2 of the reading, whichever is greater; the minimum detection limit is -0.05% O2 Zirconia analyzer repeatability: ±0.5% of full scale Zirconia analyzer basic error: ≤±0.5% (full scale) Zirconia analyzer stability: ≤±0.5% (instrument continuous calibration for 4h) Zirconia analyzer response time: 90% response within 5 seconds. (Measured from when the gas enters the calibration gas inlet and the analog signal begins to change.) Zirconia probe material: 304, 316L, 310S, HC (optional) Zirconia probe protective tube diameter: φ45mm (default), φ32mm, φ38mm, φ51mm Zirconia probe flange: JIS-5K-65-FF (standard), can be specified by the customer (DN50/DN65/DN80/DN100) Zirconia probe heating furnace resistance: 55-65Ω (other resistance values can be customized.) Zirconia protection level: IP65 Zirconia analyzer calibration method: Semi-automatic calibration, full-automatic calibration optional. Zirconia analyzer ambient temperature: -10℃~55℃ Zirconia analyzer sample gas temperature: ≤700℃ Zirconia analyzer flue gas flow rate: 0-50m/s Sample gas pressure range: -30kpa~+5kpa (high-pressure scheme can be customized.) Zirconia probe installation angle: Horizontal, vertical downward. Zirconia analyzer calibration gas: 5% and 20.6% O2, background gas is nitrogen. Calibration gas flow rate: 150-300 ml/min Self-diagnosis information: Thermocouple reverse connection, thermocouple disconnection, heating abnormality, temperature upper and lower limit alarm, oxygen upper and lower limit alarm. Anhui Tianfen Instrument Co., Ltd. produces zirconia oxygen analyzers, which are divided into: high-oxygen analyzers, constant oxygen analyzers, and trace oxygen analyzers. High-oxygen analyzers are mainly used in: air separation oxygen production industry, oxygen generator outlet, mixed gas system, air-oxygen mixer, enriched oxygen pipeline, etc. Constant oxygen analyzers are mainly used in: coal-fired power plants, garbage incineration power plants, hazardous waste incineration power plants, gas boilers, oil boilers, biomass boilers, acid production boilers, steel plant heating furnaces, hot blast stoves, steel plant sintering machines, steel plant power plants, steel plant coal smoke pipelines, coking plant coke oven flues, sugar factory boilers, chemical boilers, chemical devices, chemical hydrogenation devices, chemical raw material production, oil transportation pipeline booster stations, oilfield work stations, offshore oil platforms, ship engine rooms, cruise ship engine exhaust pipes, exhaust emission pipelines, etc. Trace oxygen analyzers are mainly used in: nitrogen generators, inert gases, wave soldering, reflow soldering, microelectronics manufacturing, metal material annealing furnaces, heating furnaces, rotary furnaces, lithium battery production, kilns, trolley furnaces, ceramic production kilns, glass production kilns, pharmaceutical glass production enterprises, pharmaceutical factories, etc. According to the form of the zirconia analyzer, it is divided into: plug-in split-type zirconia analyzer, plug-in split-type explosion-proof zirconia analyzer, plug-in integrated zirconia analyzer, plug-in integrated explosion-proof zirconia analyzer, high-temperature guiding split-type zirconia analyzer, high-temperature guiding integrated zirconia analyzer, high-temperature guiding split-type explosion-proof zirconia analyzer, high-temperature guiding integrated explosion-proof zirconia analyzer, high-temperature suction split-type zirconia analyzer, high-temperature suction integrated zirconia analyzer, high-temperature suction split-type explosion-proof zirconia analyzer, high-temperature suction integrated explosion-proof zirconia analyzer, panel-mounted zirconia analyzer, desktop zirconia analyzer, etc. Our company's zirconia oxygen analyzers can provide personalized customization services for customers. We can provide OEM processing services for various instrument integrators, and provide customized power-on welcome interface and power-on logo display. Our zirconia oxygen analyzers have comprehensive functions. In addition to the standard 4-20mA output, the zirconia oxygen analyzer also has optional RS485 communication, HART protocol communication, mobile phone Bluetooth connection, automatic calibration, automatic purging, etc. It can be said that our zirconia oxygen analyzer is a full-featured one. As long as you make a request, we will meet your needs. Our zirconia oxygen analyzers have high accuracy, high stability, high reliability, long-term non-drift, and high cost performance. Welcome customers and instrument integrators in need to contact us for cooperation. Anhui Tianfen Instrument Co., Ltd. - Focusing on the research and development and production of gas analyzers. Domestic high-end zirconia analyzer professional manufacturer. Contact person: Pan Xueliang 18225808093

Keywords: R&D tuning fork densimeter, zirconia oxygen analyzer

氧气分析仪 氧气浓度分析仪 TFEX-8氧化锆氧量分析仪 微量氧分析仪 氧分析仪 电厂氧化锆分析仪 钢厂氧化锆分析仪 焦化厂氧化锆氧量分析仪 空分氧气分析仪 富氧燃烧氧含量分析仪

Product Details

TFYHG™ oxygen content analyzer for oxy-fuel combustion is an oxygen analyzer, also known as an oxygen concentration analyzer, mainly used for measuring the oxygen content of boiler flue gas. Flue gas oxygen content is one of the important monitoring parameters for boiler operation and an important indicator reflecting the perfection of combustion equipment and boiler operation. Its value is related to factors such as boiler structure, type and properties of fuel, boiler load, operating air distribution conditions, and equipment sealing conditions. The smaller the oxygen content, i.e., the smaller the excess air coefficient, the greater the increase in chemical incomplete combustion heat loss and mechanical incomplete combustion heat loss; the larger the oxygen content, i.e., the larger the excess air coefficient, the greater the amount of air supplied. Excess air causes a decrease in furnace temperature, which not only affects combustion but also carries away a large amount of heat and dust, increasing the calculated result of pollution emission concentration. At the same time, a large air volume also increases the exhaust gas power consumption. Controlling the flue gas oxygen content is of great significance to controlling the combustion process and achieving safe, efficient, and low-pollution emissions.

Technical parameters of the oxygen analyzer are as follows:

Model: TFYHG™ Oxygen Content Analyzer for Oxy-fuel Combustion

Zirconia analyzer display screen: LCD

Zirconia analyzer operating language: Chinese (English optional)

Zirconia analyzer power supply: 200-245V AC 50~60Hz

Zirconia transmitter power: ≤150W

Zirconia transmitter output signal: 4~20mA

Zirconia analyzer range: Factory default 0.01%-25%. Optional 0.01ppm-20000ppm, 0.01%-100%

Zirconia analyzer communication: HART/485 (optional)

Zirconia analyzer alarm: 1-way switch output (optional)

Zirconia analyzer instrument accuracy: ±0.75% or 0.05% O2 of the reading, whichever is larger; the minimum detection limit is -0.05% O2

Zirconia analyzer repeatability: ±0.5% of full scale

Zirconia analyzer basic error: ≤±0.5% (full scale)

Zirconia analyzer stability: ≤±0.5% (instrument continuous verification for 4h)

Zirconia analyzer response time: 90% response within 5 seconds. (Measured from when the gas enters the calibration gas inlet and the analog signal begins to change.)

Zirconia probe material: 304, 316L, 310S, HC (optional)

Zirconia probe protective tube diameter: φ45mm (default), φ32mm, φ38mm, φ51mm

Zirconia probe flange: JIS-5K-65-FF (standard), can be specified by the customer (DN50/DN65/DN80/DN100)

Zirconia probe heating furnace resistance: 55-65Ω (other resistance values can be customized.)

Zirconia protection level: IP65

Zirconia analyzer calibration method: Semi-automatic calibration, full-automatic calibration optional.

Zirconia analyzer ambient temperature: -10℃ ~55℃

Zirconia analyzer sample gas temperature: ≤ 700℃

Zirconia analyzer flue gas velocity: 0-50m/s

Sample gas pressure range: -30kpa~﹢5kpa (high-pressure scheme can be customized.)

Zirconia probe installation angle: Horizontal, vertical downward.

Zirconia analyzer calibration gas: 5% and 20.6% O2, background gas is nitrogen. Calibration gas flow rate: 150-300 ml/min

Self-diagnosis information: Thermocouple reverse connection, thermocouple disconnection, heating abnormality, temperature upper and lower limit alarm, oxygen upper and lower limit alarm.

Zirconia oxygen analyzers produced by Anhui Tianfen Instrument Co., Ltd. are divided into: high-oxygen analyzers, constant oxygen analyzers, and trace oxygen analyzers.

High-oxygen analyzers are mainly used in: air separation oxygen production industry, oxygen generator outlet, mixed gas system, air-oxygen mixer, enriched oxygen pipeline, etc.

Constant oxygen analyzers are mainly used in: coal-fired power plants, garbage incineration power plants, hazardous waste incineration power plants, gas boilers, oil boilers, biomass boilers, acid production boilers, steel plant heating furnaces, hot blast stoves, steel plant sintering machines, steel plant power plants, steel plant coal smoke pipelines, coking plant coke oven flues, sugar factory boilers, chemical boilers, chemical devices, chemical hydrogenation devices, chemical raw material production, oil transportation pipeline booster stations, oilfield work stations, offshore oil platforms, ship engine rooms, cruise ship engine exhaust pipes, exhaust emission pipelines, etc.

Trace oxygen analyzers are mainly used in: nitrogen generators, inert gases, wave soldering, reflow soldering, microelectronics manufacturing, metal material annealing furnaces, heating furnaces, rotary furnaces, lithium battery production, kilns, car bottom furnaces, ceramic production kilns, glass production kilns, pharmaceutical glass production enterprises, pharmaceutical factories, etc.

Zirconia analyzers are categorized as follows: plug-in split-type zirconia analyzer, plug-in split-type explosion-proof zirconia analyzer, plug-in integrated zirconia analyzer, plug-in integrated explosion-proof zirconia analyzer, high-temperature flow-guided split-type zirconia analyzer, high-temperature flow-guided integrated zirconia analyzer, high-temperature flow-guided split-type explosion-proof zirconia analyzer, high-temperature flow-guided integrated explosion-proof zirconia analyzer, high-temperature suction-type split zirconia analyzer, high-temperature suction-type integrated zirconia analyzer, high-temperature suction-type split explosion-proof zirconia analyzer, high-temperature suction-type integrated explosion-proof zirconia analyzer, panel-mounted zirconia analyzer, and benchtop zirconia analyzer.

Our company's zirconia oxygen analyzers offer personalized customization services. We provide OEM services for various instrument integrators, including customized startup welcome interfaces and startup logo displays. Our zirconia oxygen analyzers are fully functional, including standard 4-20mA output, and optional RS485 communication, HART protocol communication, mobile phone Bluetooth connection, automatic calibration, and automatic purging. Our zirconia oxygen analyzers are truly full-featured. Just let us know your requirements, and we will meet them.

Our zirconia oxygen analyzers boast high accuracy, high stability, high reliability, long-term drift-free performance, and high cost-effectiveness. We welcome customers and instrument integrators to contact us for cooperation.

Anhui Tianfen Instrument Co., Ltd. - Focusing on the research and development and production of gas analyzers.

A professional manufacturer of high-end zirconia analyzers in China.

Contact Person: Pan Xueliang 18225808093

Online Ordering

If you have any needs, please feel free to contact us

Submit