VDK-T8800BH Zirconia sensor Zirconia oxygen analyzer BW3000

Integrated explosion-proof zirconia oxygen analyzer, high-precision model, truly integrated explosion-proof. Zirconia sensor VDK-T8800BH Zirconia oxygen analyzer BW3000 Zirconia sensor VDK-T8800BH Zirconia oxygen analyzer BW3000 Product Model: TFEX-8 Explosion-proof mark: Exdb IIC T6 Gb Protection class: IP66 Structure: Integrated Material: Cast aluminum Size: 270×230×110 (mm) Display: LCD Operating language: Chinese (English optional) Power supply: 200-245V AC 50~60Hz Power: ≤150W Output signal: 4~20mA Measurement range: Factory default 0.01%-25%. Optional 0.01ppm-20000ppm, 0.01%-100% Communication: HART/485 (optional) Alarm: 1 way switch output (optional) Instrument accuracy: ±0.75% of reading or 0.05% O2, whichever is greater; minimum detection limit is –0.05% O2 Repeatability: ±0.5% of full scale Basic error: ≤±0.5% (full scale) Stability: ≤±0.5% (instrument continuous verification for 4h) Response time: 90% response within 5 seconds. (Measured from when gas enters the calibration gas inlet and analog signal begins to change.) Probe material: 304, 316L, 310S, HC (optional) Protection tube diameter: φ45mm (default), φ32mm, φ38mm, φ51mm Flange: JIS-5K-65-FF (standard), can be specified by customer (DN50/DN65/DN80/DN100) Heating furnace resistance: 55-65Ω (other resistance values can be customized.) Calibration method: Semi-automatic calibration, optional fully automatic calibration. Ambient temperature: -10℃~55℃ Sample gas temperature: 0-1200℃ Flue gas velocity: 0-50m/s Sample gas pressure range: -30kpa~﹢5kpa (High pressure solution can be customized.) Probe installation angle: Horizontal, vertically downward. Calibration gas: 5% and 20.6% O2, background gas is nitrogen. Standard gas flow: 150-300 ml/min Self-diagnosis information: Thermocouple reverse connection, thermocouple open circuit, heating abnormal, temperature upper/lower limit alarm, oxygen content upper/lower limit alarm. Anhui Tianfen Instrument Co., Ltd. Specializing in R&D and production of gas analyzers, a professional manufacturer of high-end zirconia oxygen analyzers. Contact person: Pan Xueliang 18225808093

Keywords: R&D tuning fork densimeter, zirconia oxygen analyzer

一体式防爆氧化锆氧量分析仪 一体防爆氧化锆 防爆型氧化锆氧量分析仪 低氧分析仪 一体化氧气分析仪 一体化智能氧含量分析仪

Product Details

Zirconia sensor VDK-T8800BH

BW3000 Zirconia Oxygen Analyzer

Integrated explosion-proof zirconia oxygen analyzer, high-precision model, truly integrated explosion-proof.

Suitable for various industries.

Zirconia product model: Zirconia sensor VDK-T8800BH

Zirconia explosion-proof mark: Exdb IIC T6 Gb

Zirconia protection level: IP66

Zirconia structure: Integrated

Material: Cast aluminum Size: 270×230×110 (mm)

Display: LCD

Operating language: Chinese (English optional)

Power supply: 200-245V AC 50~60Hz

Power consumption: ≤150W

Output signal: 4~20mA

Range: Factory default 0.01%-25%. Optional 0.01ppm-20000ppm, 0.01%-100%

Communication: HART/485 (optional)

Alarm: 1-way switch output (optional)

Instrument accuracy: ±0.75% of reading or 0.05% O2, whichever is greater; minimum detection limit is -0.05% O2

Repeatability: ±0.5% of full scale

Basic error: ≤±0.5% (full scale)

Stability: ≤±0.5% (instrument continuous calibration for 4h)

Response time: 90% response within 5 seconds. (Measured from when the gas enters the calibration gas inlet and the analog signal begins to change.)

Probe material: 304, 316L, 310S, HC (optional)

Protective tube diameter: φ45mm (default), φ32mm, φ38mm, φ51mm

Flange: JIS-5K-65-FF (standard), can be specified by customer (DN50/DN65/DN80/DN100)

Heating furnace resistance: 55-65Ω (other resistance values can be customized.)

Calibration method: Semi-automatic calibration, full-automatic calibration optional.

Ambient temperature: -10℃ ~55℃

Sample gas temperature: 0-1200℃

Flue gas flow rate: 0-50m/s

Sample gas pressure range: -30kpa~﹢5kpa (high-pressure solution can be customized.)

Probe installation angle: Horizontal, vertical downward.

Calibration gas: 5% and 20.6% O2, background gas is nitrogen. Calibration gas flow rate: 150-300 ml/min

Self-diagnosis information: Thermocouple reverse connection, thermocouple disconnection, heating abnormality, upper and lower temperature alarm, upper and lower oxygen limit alarm.

 

Zirconia sensor VDK-T8800BH

BW3000 Zirconia Oxygen Analyzer

 

Our company's zirconia oxygen analyzer products can provide personalized customization services for customers. We can provide OEM services for various instrument integrators, providing customized startup welcome interfaces and startup logo displays. Our zirconia oxygen analyzers have comprehensive functions. In addition to the standard 4-20mA output, the zirconia oxygen analyzer also has optional RS485 communication, HART protocol communication, mobile phone Bluetooth connection, automatic calibration, and automatic purging functions. It can be said that our zirconia oxygen analyzer is a full-featured one. As long as you make a request, we will meet your needs.

Our zirconia oxygen analyzers have high accuracy, high stability, high reliability, long-term drift-free, and high cost performance. Welcome customers and instrument integrators in need to contact us for cooperation.

 

Zirconia sensor VDK-T8800BH

BW3000 Zirconia Oxygen Analyzer

 

Zirconia sensor VDK-T8800BH

BW3000 Zirconia Oxygen Analyzer

Anhui Tianfen Instrument Co., Ltd.

Focus on the research and development and production of gas analyzers, and is a professional manufacturer of high-end zirconia oxygen analyzers.

Contact person: Pan Xueliang 18225808093

Online Ordering

If you have any needs, please feel free to contact us

Submit