TFYHG™ Zirconia Oxygen Analyzer Residual Oxygen Analyzer
Keywords: R&D tuning fork densimeter, zirconia oxygen analyzer
Category:
Product Details
The cost-effective zirconia analyzer developed and produced by Anhui Tianfen Instrument Co., Ltd. features temperature auto-tuning and a temperature control accuracy of ±0.1℃. It can be used with zirconia probes from all zirconia manufacturers on the market. Thermocouple types K, R, and S are optional. It includes automatic purging and automatic calibration functions.
Main technical parameters of the high-performance zirconia analyzer:
Model: TFYHG™ Zirconia Oxygen Analyzer Residual Oxygen Analyzer
TFYHG Zirconia Analyzer Display: LCD
Zirconia Analyzer Operating Language: Chinese (English optional)
Zirconia Power Supply: 200-245V AC 50~60Hz
Zirconia Analyzer Power: ≤150W
Zirconia Analyzer Output Signal: 4 ~20mA
Zirconia Analyzer Range: Factory default 0.01%-25%. Optional 0.01ppm-20000ppm, 0.01%-100%
Zirconia Analyzer Temperature Control Accuracy: ±0.1℃
Zirconia Analyzer Thermocouple: K-type, Optional R-type, S-type
Zirconia Analyzer Communication: HART/485 (optional)
Zirconia Analyzer Alarm: 1 way switch output (optional)
Zirconia Instrument Accuracy: ±0.75% of reading or 0.05% O2, whichever is greater; minimum detection limit is –0.05% O2
Zirconia Repeatability: ±0.5% of full scale
Zirconia Probe Basic Error: ≤±0.5% (full scale)
Zirconia Analyzer Stability: ≤±0.5% (instrument continuously verified for 4h)
Zirconia Probe Sensor Response Time: 90% response within 5 seconds. (Measured from when gas enters the calibration gas inlet and analog signal begins to change.)
Zirconia Probe Material: 304, 316L, 310S, HC (optional)
Zirconia Probe Protection Tube Diameter: φ45mm (default), φ32mm, φ38mm, φ51mm
Zirconia Probe Flange: JIS-5K-65-FF (standard), customizable by customer (DN50/DN65/DN80/DN100)
Zirconia Probe Heating Furnace Resistance: 55-65Ω (other resistance values can be customized.)
Zirconia Oxygen Analyzer Protection Level: IP65
Zirconia Analyzer Calibration Method: Semi-automatic calibration, optional full-automatic calibration.
Zirconia Transmitter Ambient Temperature: -10℃ ~55℃
Zirconia Probe Sample Gas Temperature: ≤ 700℃
Zirconia Probe Flue Gas Flow Rate: 0-50m/s
Zirconia Probe Applicable Sample Gas Pressure Range: -30kpa~﹢5kpa (high pressure solution can be customized.)
Zirconia Probe Installation Angle: Horizontal, vertically downward.
Zirconia Calibration Gas: 5% and 20.6% O2, background gas is nitrogen. Calibration gas flow: 150-300 ml/min
Zirconia Analyzer Self-Diagnosis Information: Thermocouple reverse connection, thermocouple open circuit, heating abnormal, temperature upper/lower limit alarm, oxygen content upper/lower limit alarm.
Zirconia Oxygen Analyzer Model: TFOY-16NCH-F8 Integrated Zirconia Residual Oxygen Analyzer
Anhui Tianfen Instrument Co., Ltd. - Specializing in R&D and production of gas analyzers
Professional Manufacturer of Zirconia Oxygen Analyzers
Contact Person: 潘学良 Phone: 18225808093