Zirconia analyzer for TFZRO titanium alloy annealing furnace
Keywords: R&D tuning fork densimeter, zirconia oxygen analyzer
Category:
Product Details
Zirconia analyzers are used in titanium alloy annealing furnaces. A dedicated zirconia analyzer for titanium alloy annealing furnaces is launched to achieve low oxygen control and make the titanium alloy achieve a bright effect.
Main technical parameters of zirconia analyzer zirconia probe:
Model: TFZRO™
Zirconia analyzer display: LCD
Zirconia analyzer operating language: Chinese (English optional)
Zirconia power supply: 200-245V AC 50~60Hz
Zirconia analyzer power: ≤150W
Zirconia analyzer output signal: 4~20mA
Zirconia analyzer range: Factory default 0.01%-25%. Optional 0.01ppm-20000ppm, 0.01%-100%
Zirconia analyzer communication: HART/485 (optional)
Zirconia analyzer alarm: 1-way switch output (optional)
Zirconia instrument accuracy: ±0.75% or 0.05% O2 of the reading, whichever is larger; the minimum detection limit is -0.05% O2
Zirconia repeatability: ±0.5% of full scale
Zirconia probe basic error: ≤±0.5% (full scale)
Zirconia analyzer stability: ≤±0.5% (instrument continuous calibration for 4h)
Zirconia probe sensor response time: 90% response within 5 seconds. (Measured from when the gas enters the calibration gas inlet and the analog signal begins to change.)
Zirconia probe material: 304, 316L, 310S, HC (optional)
Zirconia probe protective tube diameter: φ45mm (default), φ32mm, φ38mm, φ51mm
Zirconia probe flange: JIS-5K-65-FF (standard), can be specified by customer (DN50/DN65/DN80/DN100)
Zirconia probe heating furnace resistance: 55-65Ω (other resistance values can be customized.)
Zirconia oxygen analyzer protection level: IP65
Zirconia analyzer calibration method: Semi-automatic calibration, optional full-automatic calibration.
Zirconia transmitter ambient temperature: -10℃ ~55℃
Zirconia probe sample gas temperature: ≤ 700℃
Zirconia probe flue gas flow rate: 0-50m/s
Zirconia probe applicable sample gas pressure range: -30kpa~﹢5kpa (high pressure scheme can be customized.)
Zirconia probe installation angle: Horizontal, vertical downward.
Zirconia calibration gas: 5% and 20.6% O2, background gas is nitrogen. Calibration gas flow rate: 150-300 ml/min
Zirconia analyzer self-diagnosis information: Thermocouple reverse connection, thermocouple disconnection, heating abnormality, temperature upper and lower limit alarm, oxygen upper and lower limit alarm.
Incineration of garbage, medical waste, and solid waste; annealing furnaces, heating furnaces, coking plants use zirconia oxygen analyzers
Zirconia oxygen analyzer Model: TFZO-5 TFZRO Power plant zirconia oxygen analyzer Model: C series zirconia oxygen analyzer Power plant zirconia analyzer Model: TKZO-5 Power plant zirconia analyzer Model: ZrO2-5 Power plant zirconia oxygen meter Model: NFZrO2-5 Power plant zirconia oxygen meter I series Power plant zirconia Model 3000 series Power plant zirconia analyzer TKFX-ZOA-5 ZO-12B zirconia oxygen analyzer
Our company's zirconia oxygen analyzers can provide personalized customization services for customers. We can provide OEM processing services for various instrument integrators, providing customized power-on welcome interfaces and power-on logo displays. Our zirconia oxygen analyzers have comprehensive functions. In addition to the standard 4-20mA output, the zirconia oxygen analyzer also has optional RS485 communication, HART protocol communication, mobile phone Bluetooth connection, automatic calibration, automatic purging, etc. It can be said that our zirconia oxygen analyzer is a full-featured one. As long as you make a request, we will meet your needs.