TFEX-8 explosion-proof zirconia oxygen analyzer, zirconia oxygen analyzer BW3000, zirconia sensor VDK-T8800BH

TFEX-8 explosion-proof zirconia oxygen analyzer, explosion-proof grade Exd II CT6

Keywords: R&D tuning fork densimeter, zirconia oxygen analyzer

氧化锆氧量分析仪BW3000 氧化锆传感器VDK-T8800BH 氧化锆氧量分析仪BW3000 氧化锆传感器VDK-T8800BH

Product Details

 Zirconia Oxygen Analyzer BW3000 Zirconia Sensor VDK-T8800BH

Zirconia Oxygen Analyzer BW3000 Zirconia Sensor VDK-T8800BH

 TFEX-8 Explosion-proof Zirconia Oxygen Analyzer Explosion-proof Grade Exd II CT6

  Explosion-proof Zirconia Oxygen Analyzer Model: TFEX-8

  Explosion-proof Mark for Zirconia: Exdb IIC T6 Gb

  Protection Level: IP66

  Material: Cast Aluminum Size: 270×230×110 (mm)

  Display: LCD

  Operating Language: Chinese (English optional)

  Power Supply: 200-245V AC 50~60Hz

  Power Consumption: ≤150W

  Output Signal: 4~20mA

  Range: Factory default 0.01%-25%. Optional 0.01ppm-20000ppm, 0.01%-100%

  Communication: HART/485 (optional)

  Alarm: 1-way switch output (optional)

  Instrument Accuracy: ±0.75% of reading or 0.05% O2, whichever is greater; Detection limit is –0.05% O2

  Repeatability: ±0.5% of full scale

  Basic Error: ≤±0.5% (full scale)

  Stability: ≤±0.5% (instrument continuous verification for 4h)

  Response Time: 90% response within 5 seconds. (Measured from when gas enters the calibration gas inlet and the analog signal begins to change.)

  Probe Material: 304, 316L, 310S, HC (optional)

  Protective Tube Diameter: φ45mm (default), φ32mm, φ38mm, φ51mm

  Flange: JIS-5K-65-FF (standard), can be specified by customer (DN50/DN65/DN80/DN100)

  Heating Furnace Resistance: 55-65Ω (other resistance values can be customized.)

  Calibration Method: Semi-automatic calibration, full-automatic calibration optional.

  Ambient Temperature: -10℃~55℃

  Sample Gas Temperature: ≤700℃

  Flue Gas Velocity: 0-50m/s

  Sample Gas Pressure Range: -30kpa~﹢5kpa (high-pressure solution can be customized.)

  Probe Installation Angle: Horizontal, vertical downward.

  Calibration Gas: 5% and 20.6% O2, background gas is nitrogen. Calibration gas flow rate: 150-300 ml/min

  Self-diagnosis Information: Thermocouple reverse connection, thermocouple disconnection, heating abnormality, upper and lower temperature limit alarm, upper and lower oxygen limit alarm.

  Sulfuric Acid Plant Dedicated [ZO-801S Zirconia Oxygen Analyzer]

  [ZO-801S Zirconia Oxygen Analyzer] is a gas online monitoring system made of special materials. This instrument has all the functions of a common zirconia oxygen analyzer and has corrosion resistance. It has been used in harsh environments such as chemical industry, garbage incineration, and sulfuric acid plants in China.

   [ZO-801S Zirconia Oxygen Analyzer] Features:

  Easy Installation

  High Accuracy

  Stable Performance

  Long Probe Life

  High Protection Level

   [ZO-801S Zirconia Oxygen Analyzer] Main Technical Parameters:

  Range: 0-25% or 0-20.6%

  Accuracy: 0.5%

  Temperature Range: 0-750 degrees

  Repeatability: ±0.5% of full scale

  Power Supply and Consumption: Power supply 220±10%VAC, power consumption is 150W

  Length: 0.4m; 0.8m; 1.0m; 1.2m; (Other lengths can be produced according to user requirements)

  Brand: Anhui Tianfen Instrument Co., Ltd.

  Output 4-20mA

  Flange: DN50 (outer diameter 155mm, inner diameter 130mm)

   [ZO-801S Zirconia Oxygen Analyzer] Application Cases:

  Zhalantun Xingfa Sulfuric Acid Plant, Wuxi Sulfuric Acid Plant, Changzhou Changjiang Sulfuric Acid Plant, Liaocheng Sulfuric Acid Plant, Shandong Province, Ningbo Sulfuric Acid Plant, Ningbo Sulfuric Acid Plant, Hubei Yangfeng Sulfuric Acid Plant, Shandong Fuming Sulfuric Acid Enterprises, Suzhou Sulfuric Acid Plant, Tianjin Sulfuric Acid Plant, Gongyi Sulfuric Acid, Jinzhou Sulfuric Acid Plant, Shuangying Group Co., Ltd., Yunfu Sulfuric Acid Plant, Guangdong Province, Inner Mongolia Northern Chemical Minerals Group Co., Ltd., Nanchang Minghai Industrial Sulfuric Acid Plant, etc.

   [ZO-801S Zirconia Oxygen Analyzer] Selection Specifications:

  (1) ZO-801S, L=400mm, output 4-20mA, 0-750 degrees

  (2) ZO-801S, L=500mm, output 4-20mA, 0-750 degrees

  (3) ZO-801S, L=600mm, output 4-20mA, 0-750 degrees

  (4) ZO-801S, L=700mm, output 4-20mA, 0-750 degrees

  (5) ZO-801S, L=800mm, output 4-20mA, 0-750 degrees

  (6)ZO-801S, L=900mm, output 4-20mA, 0-750 degrees

  (7)ZO-801S, L=1000mm, output 4-20mA, 0-750 degrees

  (8)ZO-801S, L=1100mm, output 4-20mA, 0-750 degrees

  (9)ZO-801S, L=1200mm, output 4-20mA, 0-750 degrees

    Zirconia Oxygen Analyzer BW3000

Zirconia Sensor VDK-T8800BH 