TFEN zirconia oxygen analyzer for garbage incineration power plants
Keywords: R&D tuning fork densimeter, zirconia oxygen analyzer
Category:
Product Details
Zirconia oxygen analyzer for garbage incineration, medical waste incineration, and solid waste incineration
Zirconia oxygen analyzer Model: TFZO-5 Power plant zirconia oxygen analyzer Model: Y series zirconia oxygen analyzer Power plant zirconia analyzer Model: TKZO-5 Power plant zirconia analyzer Model: ZrO2-5 Power plant zirconia oxygen meter Model: NFZrO2-5 Power plant zirconia oxygen meter G series Power plant zirconia Model 3000 series Power plant zirconia analyzer TKFX-ZOA-5 ZO-12B Zirconia oxygen analyzer
Model: TFEN™
Display: LCD
Operating language: Chinese (English optional)
Power supply: 200-245V AC 50~60Hz
Power: ≤150W
Output signal: 4~20mA
Range: Factory default 0.01%-25%. Optional 0.01ppm-20000ppm, 0.01%-100%
Communication: HART/485 (optional)
Alarm: 1-way switch output (optional)
Instrument accuracy: ±0.75% of reading or 0.05% O2, whichever is greater; Detection limit is –0.05% O2
Repeatability: ±0.5% of full scale
Basic error: ≤±0.5% (full scale)
Stability: ≤±0.5% (instrument continuous verification for 4h)
Response time: 90% response within 5 seconds. (Measured from when the gas enters the calibration gas inlet and the analog signal begins to change.)
Probe material: 304, 316L, 310S, HC (optional)
Protective tube diameter: φ45mm (default), φ32mm, φ38mm, φ51mm
Flange: JIS-5K-65-FF (standard), can be specified by customer (DN50/DN65/DN80/DN100)
Heating furnace resistance: 55-65Ω (other resistance values can be customized.)
Protection level: IP65
Calibration method: Semi-automatic calibration, full-automatic calibration optional.
Ambient temperature: -10℃~55℃
Sample gas temperature: ≤700℃
Flue gas velocity: 0-50m/s
Sample gas pressure range: -30kpa~﹢5kpa (high pressure scheme can be customized.)
Probe installation angle: Horizontal, vertical downward.
Calibration gas: 5% and 20.6% O2, background gas is nitrogen. Calibration gas flow rate: 150-300 ml/min
Self-diagnosis information: Thermocouple reverse connection, thermocouple disconnection, heating abnormality, upper and lower temperature limit alarm, upper and lower oxygen limit alarm.
Common models and specifications of ZOY series:
Zirconia probe ZOY-4-400 heated probe L=400 mm <600℃
Zirconia probe ZOY-4-800 heated probe L=800 mm <600℃
Zirconia probe ZOY-4-1200H heated probe L=1200 mm <600℃
Zirconia probe ZOY-5-1200 unheated probe L=1200mm 600-850℃
Oxygen transmitter ZOY-4C wall-mounted heated instrument 200×175×100(W×H×L)
Oxygen transmitter ZOY-4H panel-mounted heated instrument 160×80×350(W×H×L)
Oxygen transmitter ZOY-4F panel-mounted square heated instrument 160×160×350(W×H×L)
Oxygen transmitter ZOY-4S panel-mounted vertical heated instrument 80×160×350(W×H×L)